Targeting immune cell dynamics by longitudinal wholebody imaging and mathematical modelling
Principal investigators: Klaus Schäfers, Benedikt Wirth
Project number: CRC 1450 A05
Project term: 01/2021–12/2024
We develop strategies for tracking and quantifying (immune) cell populations or even single cells in long-term (days) whole-body PET studies in mice and humans (1). This will be achieved through novel acquisition protocols, measured and simulated phantom data (2), use of prior information from MRI and microscopy, mathematical modelling, and mathematical analysis of image reconstruction with novel regularization paradigms based on optimal transport (3).
Particular applications include imaging and tracking of macrophages and neutrophils following myocardial ischemia-reperfusion or in arthritis and sepsis (4) with a future potential to translate into clinical algorithms (5).
The names of the principal investigators in our network have been bolded. Publications released prior to 2021, when funding for our network commenced, represent previous project-related work.
2024
Holler M, Schlüter A, Wirth B. Dimension reduction, exact recovery, and error estimates for sparse reconstruction in phase space. Applied and Computational Harmonic Analysis 2024;70: 101631. Abstract
Margeta R, Schelhaas S, Hermann S, Schafers M, Niemann S, Faust A. A novel radiolabelled salmochelin derivative for bacteria-specific PET imaging: synthesis, radiolabelling and evaluation. Chem Commun (Camb) 2024Abstract
2023
Hahn B, Wirth B. Convex reconstruction of moving particles with inexact motion model. Proc Appl Math and Mech 2023;23Abstract
Holler M, Wirth B. Exact reconstruction and reconstruction from noisy data with anisotropic total variation 2023Abstract
2021
Clason C, Tameling C, Wirth B. Convex Relaxation of Discrete Vector-Valued Optimization Problems. SIAM Rev. 2021;63: 783-821. Abstract
2020
Pösse S, Büther F, Mannweiler D, Hong I, Jones J, Schäfers M, Schäfers KP. Comparison of two elastic motion correction approaches for whole-body PET/CT: motion deblurring vs gate-to-gate motion correction. EJNMMI Phys 2020;7Abstract
Schmitzer B, Schafers KP, Wirth B. Dynamic Cell Imaging in PET With Optimal Transport Regularization. IEEE Trans Med Imaging 2020;39: 1626-1635. Abstract
2019
Schmitzer B, Wirth B. Dynamic models of Wasserstein-1-type unbalanced transport. Esaim: Cocv 2019;25: 23. Abstract
Schmitzer B, Wirth B. A Framework for Wasserstein-1-Type Metrics. J. Convex Anal. 2019;26: 353-396. Abstract
2018
Bolwin K, Czekalla B, Frohwein LJ, Büther F, Schäfers KP. Anthropomorphic thorax phantom for cardio-respiratory motion simulation in tomographic imaging. Phys Med Biol 2018;63: 035009. Abstract
Clason C, Tameling C, Wirth B. Vector-Valued Multibang Control of Differential Equations. SIAM J. Control Optim. 2018;56: 2295-2326. Abstract
Frohwein LJ, Hess M, Schlicher D, Bolwin K, Büther F, Jiang X, Schäfers KP. PET attenuation correction for flexible MRI surface coils in hybrid PET/MRI using a 3D depth camera. Phys Med Biol 2018;63: 025033. Abstract
2017
Bolwin K, Vernekohl D, Lühder J, Czekalla B, Wessels JP, Schäfers KP. Development of a clear sub-millimeter small animal PET scanner by reducing the influence of the non-collinearity effect. J. Inst. 2017;12: C03006-C03006. Abstract